@@ -0,0 +1,50 @@
|
||||
---
|
||||
# nuzlocke-tracker-9xac
|
||||
title: Fix stale PostgreSQL enum causing test failures
|
||||
status: completed
|
||||
type: bug
|
||||
priority: normal
|
||||
created_at: 2026-03-21T10:27:53Z
|
||||
updated_at: 2026-03-21T10:29:33Z
|
||||
---
|
||||
|
||||
## Problem
|
||||
|
||||
The backend smoke tests fail with:
|
||||
```
|
||||
sqlalchemy.exc.DBAPIError: invalid input value for enum run_visibility: "public"
|
||||
```
|
||||
|
||||
This happens during `Base.metadata.create_all` in the `engine` fixture (`backend/tests/conftest.py:27`).
|
||||
|
||||
## Root Cause
|
||||
|
||||
The `engine` fixture only calls `create_all` during setup and `drop_all` during teardown. If a previous test run was interrupted before teardown, the `run_visibility` PostgreSQL enum type persists in the test database with stale/incorrect values. On the next run, `create_all` (with `checkfirst=True` default) sees the enum exists and skips recreating it, but the existing enum lacks valid values, causing the `DEFAULT 'public'` to fail.
|
||||
|
||||
PostgreSQL native enum types are not automatically dropped with `DROP TABLE` — they require explicit `DROP TYPE`.
|
||||
|
||||
## Fix
|
||||
|
||||
In the `engine` fixture at `backend/tests/conftest.py:23-31`, add `Base.metadata.drop_all` before `create_all` to ensure a clean slate:
|
||||
|
||||
```python
|
||||
@pytest.fixture(scope="session")
|
||||
async def engine():
|
||||
eng = create_async_engine(TEST_DATABASE_URL, echo=False)
|
||||
async with eng.begin() as conn:
|
||||
await conn.run_sync(Base.metadata.drop_all) # <-- add this
|
||||
await conn.run_sync(Base.metadata.create_all)
|
||||
yield eng
|
||||
async with eng.begin() as conn:
|
||||
await conn.run_sync(Base.metadata.drop_all)
|
||||
await eng.dispose()
|
||||
```
|
||||
|
||||
## Checklist
|
||||
|
||||
- [x] Add `drop_all` before `create_all` in the `engine` fixture (`backend/tests/conftest.py`)
|
||||
- [x] Verify tests pass with `pytest backend/tests/test_smoke.py`
|
||||
|
||||
## Summary of Changes
|
||||
|
||||
Added `drop_all` before `create_all` in the test engine fixture to ensure stale PostgreSQL enum types are cleared before recreating the schema. This prevents test failures when a previous test run was interrupted before cleanup.
|
||||
@@ -24,6 +24,7 @@ async def engine():
|
||||
"""Create the test engine and schema once for the entire session."""
|
||||
eng = create_async_engine(TEST_DATABASE_URL, echo=False)
|
||||
async with eng.begin() as conn:
|
||||
await conn.run_sync(Base.metadata.drop_all)
|
||||
await conn.run_sync(Base.metadata.create_all)
|
||||
yield eng
|
||||
async with eng.begin() as conn:
|
||||
|
||||
Reference in New Issue